Slide background




Il nuovo Standard ISO 24119 e il massimo PL raggiungibile in caso di serie di dispositivi di interblocco

ID 1610 | | Visite: 13412 | Documenti Estratti NormePermalink: https://www.certifico.com/id/1610




ISO/DTR 24119
Safety of machinery - Evaluation of fault masking serial connection of guard interlocking devices with potential free contacts.

This is currently under committee review, with an expectation that it will be available quite soon as ISO/TR 24119.

This TR has not been published but it will deal with.

The Technical Report illustrates and explains principles of fault masking in applications where multiple interlocking devices with potential free contacts are connected in series to one logic unit which does the diagnostics.

It provides also a guide how to estimate the probability of fault masking and the maximum DC for the involved position switches.

In simple terms, if we have more than one frequently opened guard (once per hour) the level of Diagnostic Coverage falls to zero, which in EN ISO 13849-1 results in a maximum PLc.

It remains to be seen exactly what ISO/PDTR 24119 has to say about the maximum PL achievable when several infrequently operated guards are connected, but it is very likely to be PLd where careful analysis is possible (for example, the number of guards, the type of switches, type of wiring, distance between guards, and accessibility of guards), otherwise it is more likely to be PLc.

It is definitely not possible to achieve PL e with more than one guard switch connected in series, at least not when using volt-free based interlock switch technology.

Early signs are that the technical report ISO/PDTR 24119 will provide two methods for evaluating the extent to which diagnostic coverage is impacted by masking:

1. Simplified method for the determination of the maximum achievable DC

Table 1 provides a simplified approach for the determination of the maximum achievable DC taking into account the probability of masking.

If the maximum achievable DC resulting from the application of this table does not meet the required level, the more detailed approach given in 2 may be more suitable - but this is not ideal.


2. Regular method for the determination of the maximum achievable DC

2.1 Estimation of the fault masking probability

The probability of fault masking is dependent on several parameters that should be considered, including:

  • Number of series connected devices
  • Actuation frequency of each movable guard
  • Distance between the movable guards
  • Accessibility of the movable guards
  • Number of operators

The maximum achievable DC depends on the fault masking probability level (FM) and the type of cabling used in combination with the switch arrangement and the diagnostic capabilities of the overall system to detect faults.

Tables 3 to 5 show the maximum reachable DC depending on those parameters.

In any case, if it is foreseeable that fault masking will occur (eg multiple movable guards will be open at the same time as part of normal operation or service), then the DC is limited to none.

It is beyond the scope of this article to go into the details of tables 3 and 5 referred to above, and it is recommended that, instead, the 'simplified method outlined in 2 above is used.
...
in allegato Preview

Descrizione Livello Dimensione Downloads
Allegato riservato ISO TR 24119 2015 Preview.pdf
 
270 kB 13

Tags: Normazione EN ISO 14119 Abbonati Normazione

Articoli correlati

Ultimi archiviati Normazione

UNI EN ISO 56000 2021 Gestione innovazione
Lug 06, 2024 145

UNI EN ISO 56000:2021

UNI EN ISO 56000:2021 / Gestione dell'innovazione ID 22197 | 06.07.2024 / Preview allegata UNI EN ISO 56000:2021Gestione dell'innovazione - Fondamenti e vocabolario Data disponibilità: 18 febbraio 2021 La norma, parte della serie ISO 56000, fornisce il vocabolario, i concetti fondamentali ed i… Leggi tutto
Giu 17, 2024 246

CEI EN 50110-2:2024

CEI EN 50110-2:2024 / Allegati nazionali esercizio impianti elettrici ID 22078 | 17.06.2024 / Preview allegata CEI EN 50110-2:2024Esercizio degli impianti elettrici - Parte 2: Allegati nazionali Classificazione CEI: 11-49Pubblicazione: 05.2024_______ La presente Parte 2 della Norma CEI EN 50110 è… Leggi tutto
Giu 17, 2024 347

CEI EN 50110-1:2024

CEI EN 50110-1:2024 / Prescrizioni generali esercizio impianti elettrici ID 22077 | 17.06.2024 / Preview allegata CEI EN 50110-1:2024Esercizio degli impianti elettrici - Parte 1: Prescrizioni generali Classificazione CEI: 11-48Pubblicazione: 05.2024_______ La Norma CEI EN 50110-1 si applica a tutte… Leggi tutto
Giu 15, 2024 264

UNI EN ISO 7730:2006

UNI EN ISO 7730:2006 / Benessere termico con il calcolo degli indici PMV e PPD ID 22068 | 15.06.2024 / Preview in allegato Ergonomia degli ambienti termici - Determinazione analitica e interpretazione del benessere termico mediante il calcolo degli indici PMV e PPD e dei criteri di benessere… Leggi tutto

Più letti Normazione