Il nuovo Standard ISO 24119 e il massimo PL raggiungibile in caso di serie di dispositivi di interblocco

ID 1610 | | Visite: 13745 | Documenti Estratti NormePermalink: https://www.certifico.com/id/1610




ISO/DTR 24119
Safety of machinery - Evaluation of fault masking serial connection of guard interlocking devices with potential free contacts.

This is currently under committee review, with an expectation that it will be available quite soon as ISO/TR 24119.

This TR has not been published but it will deal with.

The Technical Report illustrates and explains principles of fault masking in applications where multiple interlocking devices with potential free contacts are connected in series to one logic unit which does the diagnostics.

It provides also a guide how to estimate the probability of fault masking and the maximum DC for the involved position switches.

In simple terms, if we have more than one frequently opened guard (once per hour) the level of Diagnostic Coverage falls to zero, which in EN ISO 13849-1 results in a maximum PLc.

It remains to be seen exactly what ISO/PDTR 24119 has to say about the maximum PL achievable when several infrequently operated guards are connected, but it is very likely to be PLd where careful analysis is possible (for example, the number of guards, the type of switches, type of wiring, distance between guards, and accessibility of guards), otherwise it is more likely to be PLc.

It is definitely not possible to achieve PL e with more than one guard switch connected in series, at least not when using volt-free based interlock switch technology.

Early signs are that the technical report ISO/PDTR 24119 will provide two methods for evaluating the extent to which diagnostic coverage is impacted by masking:

1. Simplified method for the determination of the maximum achievable DC

Table 1 provides a simplified approach for the determination of the maximum achievable DC taking into account the probability of masking.

If the maximum achievable DC resulting from the application of this table does not meet the required level, the more detailed approach given in 2 may be more suitable - but this is not ideal.


2. Regular method for the determination of the maximum achievable DC

2.1 Estimation of the fault masking probability

The probability of fault masking is dependent on several parameters that should be considered, including:

  • Number of series connected devices
  • Actuation frequency of each movable guard
  • Distance between the movable guards
  • Accessibility of the movable guards
  • Number of operators

The maximum achievable DC depends on the fault masking probability level (FM) and the type of cabling used in combination with the switch arrangement and the diagnostic capabilities of the overall system to detect faults.

Tables 3 to 5 show the maximum reachable DC depending on those parameters.

In any case, if it is foreseeable that fault masking will occur (eg multiple movable guards will be open at the same time as part of normal operation or service), then the DC is limited to none.

It is beyond the scope of this article to go into the details of tables 3 and 5 referred to above, and it is recommended that, instead, the 'simplified method outlined in 2 above is used.
...
in allegato Preview

Descrizione Livello Dimensione Downloads
Allegato riservato ISO TR 24119 2015 Preview.pdf
 
270 kB 13

Tags: Normazione EN ISO 14119 Abbonati Normazione

Ultimi archiviati Marcatura CE

Set 21, 2024 1472

Decreto 17 settembre 2024 n. 133

Decreto 17 settembre 2024 n. 133 ID 22594 | 21.09.2024 Decreto 17 settembre 2024 n. 133 - Regolamento di modifica al decreto 29 luglio 2008, n. 146 concernente il regolamento di attuazione dell'articolo 65 del decreto legislativo 18 luglio 2005, n. 171, recante il codice della nautica da diporto.… Leggi tutto
Decreto 23 luglio n  124
Set 05, 2024 594

Decreto 23 luglio 2024 n. 124

Decreto 23 luglio 2024 n. 124 / Regolamento centri di istruzione per la nautica ID 22512 | 05.09.2024 Decreto 23 luglio 2024 n. 124 Regolamento di disciplina dei centri di istruzione per la nautica ai sensi dell'articolo 49-octies, del decreto legislativo 18 luglio 2005, n. 171. (GU n. 208 del… Leggi tutto
Ago 27, 2024 185

Decreto dirigenziale ASNFISA 2 maggio 2024

Decreto dirigenziale ASNFISA 2 maggio 2024 Disciplina per la formazione e l’aggiornamento professionale dei Direttori, Responsabili di esercizio e dei Capi servizio di impianti a fune ai sensi del decreto Ansfisa protocollo n. 0076655 del 7 dicembre 2023. Collegati[box-note]Decreto dirigenziale… Leggi tutto
Ago 27, 2024 231

Decreto ANSFISA 6 marzo 2024

Decreto ANSFISA 6 marzo 2024 Disposizioni per il personale incaricato delle verifiche periodiche annuali di impianti di traslazione di categoria “D” in servizio pubblico, ad eccezione degli ascensori inclinati, ai sensi dell’art.2 comma 9 del decreto Ansfisa protocollo n. 0076655 del 7 dicembre… Leggi tutto
Decreto ANSFISA 14 febbraio 2024
Ago 27, 2024 207

Decreto ANSFISA 14 febbraio 2024

Decreto ANSFISA 14 febbraio 2024 Adozione «Linee guida per il riconoscimento dei Centri di formazione nel settore dei sistemi di trasporto ad impianti fissi». Collegati[box-note]Regolamento (UE) 2016/424 - Impianti a fune | Testo consolidato e NTARegolamento (UE) 2016/424: Impianti a funeImpianti a… Leggi tutto

Più letti Marcatura CE

Set 04, 2022 115472

Regolamento Prodotti da Costruzione (UE) 305/2011 - CPR

Regolamento CPR (UE) 305/2011 Regolamento (UE) N. 305/2011 del Parlamento Europeo e del Consiglio del 9 marzo 2011 che fissa condizioni armonizzate per la commercializzazione dei prodotti da costruzione e che abroga la direttiva 89/106/CEE del Consiglio (Testo rilevante ai fini del SEE) (GU L 88/10… Leggi tutto