Multilateral Agreement M308
Multilateral Agreement M308
Multilateral agreement M308 under 1.5.1 of ADR concerning periodic inspection of LPG welded steel cylinders
1) This agreement concerns the periodic inspection of refìllable welded steel cylinders far the carriage of Lique.fìed Petrolewn Gas (LPG) of UN 1011, UN 1075, UN 1965, UN 1969 or UN 1978.
2) By derogation from the provisions of 6.2.3.5.1 of ADR, at the lime of periodic inspection, LPG welded steel cylinders fìlled in accordance with EN 1439 or with EN 14794 are exempted from the check of the internai conditions of the pressure receptacle required in 6.2.1.6.1 (b) of ADR.
3) This agreement only applies lo cylinders fìlled with LPG of high quality with very low potential contamination. This is deemed to be fulfilled, if only LPG conforming to the corrosion contaminants level of ISO 9162:1989, is fìlled in.
4) This agreemenl shall be valid until 31st December 2022 far the carriage on the territories of those ADR Contracting Parties signatory to this agreement. If il is revoked before then by one of the signatories, it shall remain valid until the above mentioned date only far the carriage on the territories of those ADR Contracting parties signatory to this agreement which have noi revoked it.
Done in Rome,
The competent authority for ADR in the Republic of Italy
| COUNTRY | SIGNED | REVOKED |
| Italy | 07/11/2017 | |
| France | 14/12/2017 |
Date of expiry: 31 December 2022
Explanatory letter in English
Agreement in English, in French
Articoli correlati Merci Pericolose
ADR 2019 Preview: nuovi numeri ONU per gli articoli

ADR 2019 Preview: nuovi numeri ONU da UN 3537 a UN 3548 per gli "articoli"
21.02.2019 - Documento completo in allegato Riservato Abbonati (IT)
Con l'ADR 2019 è introdotta la nuova sezione 2.5.1 con 12 ...
Multilateral Agreement M305
Multirateral Agreement M305
Leggi tuttoM305 Carriage of waste contaminated with viruses causing haemorrhagic fever
| COUNTRY | SIGNED | REVOKED |
| Belgium | 28/03/2017 | |
| Germany | 12/05/2017 | |
| Luxemb... |
Certifico s.r.l.
Sede: Via A. De Curtis, 28 - 06135 Perugia - IT
Sede: Via Madonna Alta 138/A - 06128 Perugia - IT
P. IVA: IT02442650541
Tel. 1: +39 075 599 73 63
Tel. 2: +39 075 599 73 43
Assistenza: 800 14 47 46
www.certifico.com
info@certifico.com
Sede: Via Madonna Alta 138/A - 06128 Perugia - IT
P. IVA: IT02442650541
Tel. 1: +39 075 599 73 63
Tel. 2: +39 075 599 73 43
Assistenza: 800 14 47 46
www.certifico.com
info@certifico.com
Testata editoriale iscritta al n. 22/2024 del registro periodici della cancelleria del Tribunale di Perugia in data 19.11.2024