IEC 60079-10-2:2026 / ATEX Classification of areas of explosive dust atmospheres - Status 04.2026 FDIS

IEC 60079-10-2:2026 / ATEX Classification of areas of explosive dust atmospheres - Status 04.2026 FDIS
 
Appunti Normazione
  Newsletter n. 2525 del 16 Aprile 2026  
Salve Visitatore


IEC 60079-10-2:2026 / ATEX Classification of areas of explosive dust atmospheres - Status 04.2026 Final Draft

ID 26019 | 16.04.2026 / Preview attached

IEC 60079-10-2:2026 (PRV)
Explosive atmospheres - Part 10-2: Classification of areas - Explosive dust atmospheres

Edition 3.0 04.2026. This Final Draft International Standard is an up to 6 weeks' pre-release of the official publication.

IEC 60079-10-2:2026 is concerned with the identification and classification of areas where explosive dust atmospheres and combustible dust layers are present in order to permit the proper assessment of ignition sources in such areas.

In this document, explosive dust atmospheres and combustible dust layers are treated separately. In Clause 4, area classification for explosive dust clouds is described, with dust layers acting as one of the possible sources of release. In Clause 7, other general considerations for dust layers are described.

The examples in this document are based on a system of effective housekeeping being implemented in the plant to prevent dust layers from accumulating. Where effective housekeeping is not present, the area classification includes the possible formation of explosive dust clouds from dust layers.

The principles of this document can also be followed when combustible fibres or flyings might cause a hazard.

Atmospheric conditions include variations in pressure and temperature above and below reference levels of 101,3 kPa (1 013 mbar) and 20 °C (293 K), provided that the variations have a negligible effect on the explosive properties of the combustible material. For air with normal oxygen content, typically a volume fraction of 21 % is assumed.

It does not apply to:
a) underground mining areas;
b) dusts of explosives that do not require atmospheric oxygen for combustion such as pyrophoric substances, propellants, pyrotechnics, munitions, peroxides, oxidizers, water‑reactive elements or compounds, or other similar materials;
c) catastrophic failures or rare malfunctions which are outside the conditions dealt with in this document;
d) rooms used for medical purposes;
e) domestic premises;
f) where a hazard is due to the presence of flammable gas or vapour, but the principles can be used in the assessment of a hybrid mixture (see also IEC 60079-10-1).

This document does not consider the effects of consequential damage following a fire or an explosion.
Please refer to the foreword of the document for a detailed listing of the significant technical changes from the previous edition.
...

add Preview




Info / download




Collegati
EN 60079-X: Tutte le norme ATEX della serie
EN 60079-10-2 Esempi Zone ATEX Polveri



Documenti Abbonati Sicurezza Lavoro Articoli ultimi inseriti
Documenti Abbonati Marcatura CE Articoli più letti
Documenti Abbonati Normazione Norme armonizzate
Documenti Abbonati Merci Pericolose File CEM
Documenti Abbonati Chemicals Testi consolidati
Documenti Abbonati Ambiente Vademecum
Documenti Abbonati macchine Codici
Documenti Abbonati Appunti Impianti Norme armonizzate Click
Documenti Abbonati Costruzioni Documenti Abbonati Full Plus
Documenti Abbonati Prevenzione Incendi Store





 

sono siti di:

Certifico S.r.l.
Via Antonio De Curtis 28 - 06135 Perugia - IT
Via Madonna Alta 138A - 06128 Perugia - IT
tel. +39 075 599 73 63 | +39 075 599 73 43
Assistenza 800 14 47 46

www.certifico.com
info@certifico.com

L'informativa sul trattamento dei dati personali è disponibile alla pagina Privacy.

INVIO NEWSLETTTER
Se vuoi cancellarti dall'invio della newsletter clicca qui oppure effettua il login al sito ed entra nella Tua Area Riservata, in “Modifica dati” agisci con la spunta sul box di selezione “newsletter”.


L'elenco completo di tutte le ns newsletter è qui: Archivio newsletter
 
certifico.com
Testata editoriale iscritta al n. 22/2024 registro periodici Tribunale di Perugia 19.11.2024
 
Icon Linkedin  Icona X  
Linea Footer
Certifico Srl 2000-2026 | VAT IT02442650541
Image

Sicurezza L.

Image

Ambiente

Image

Normazione

Image

Marcat. CE

Image

P. Incendi

Image

Chemicals

Image

Impianti

Image

Macchine

Image

Merci P.

Image

Costruzioni

Image

Trasporti

Image

HACCP

Certifico s.r.l.

Sede: Via A. De Curtis, 28 - 06135 Perugia - IT
Sede: Via Madonna Alta 138/A - 06128 Perugia - IT
P. IVA: IT02442650541

Tel. 1: +39 075 599 73 63
Tel. 2: +39 075 599 73 43

Assistenza: 800 14 47 46

www.certifico.com
info@certifico.com

Testata editoriale iscritta al n. 22/2024 del registro periodici della cancelleria del Tribunale di Perugia in data 19.11.2024